Chapter 4 Installing the Setup Software

82

4

[Code 1 setup]

Bar code = CODE39

[Main code length]

[32]

[Min code length]

[3]

[Send start/stop character (*)]

[_] Enable

[Inspect check-digit [Modulus 43]

[_] Enable

[Send check-digit]

[x] Enable

-----Options setup------
[Max code length output]

[x] Not used

[_] Forward

[_] Reverse

[Effective]

[32]

[Starting]

[1]

[Specify label orientation]

[x] Not used

[_] Forward

[_] Reverse

[Code 2 setup]

Bar code = Codabar

[Max code length]

[32]

[Min code length]

[3]

[Start/stop character]

[_] Do not send [x] Lower-case [_] Upper-case

[Inspect check-digit]

[_] Enable

[Send check-digit]

[x] Enable

[Type of check-digit]

Modulus 16

-----Options setup------
[Max code length output]

[x] Not used

[_] Forward

[_] Reverse

[Effective]

[32]

[Starting]

[1]

[Specify label orientation]

[x] Not used

[_] Forward

[_] Reverse

[Code 3 setup]

Bar code = UPC/EAN

[Read EAN 13(UPC-A)]

[x] Enable

[Read EAN 8]

[x] Enable

[Read UPC-E]

[x] Enable

[No. of UPC-A output]

[x]

13 digits

[x] 12 digits

[Add UPC-E system code 0]

[x] Do not add

[_] Add

-----Options setup-----
[Max code length output]

[x] Not used

[_] Forward

[_] Reverse

[Effective]

[32]

[Starting]

[1]

[Specify label orientation]

[x] Not used

[_] Forward

[_] Reverse

[Code 4 setup]

Bar code = None