KEYENCE BL-700 Series User Manual

Page 110

Advertising
background image

Chapter 5 Serial Communication

96

5

Function

Command being

Response

Description

Error

sent

code

Change

WCm42n

OK

m=0 to 3: Codes 1 to 4 00, 02,

Confirm

RCm42

42n

n=0: Disable

03, 04,

1: Enable

05, 07,

Change

WCm43n

OK

m=0 to 3: Codes 1 to 4 14

Confirm

RCm43

43n

n=0:Output in 13 digits

1:Output in 12 digits

Change

WCm44n

OK

m=0 to 3: Codes 1 to 4

Confirm

RCm44

44n

n=0: Disable

1: Enable

Change

WCm51n

OK

m=0 to 3: Codes 1 to 4

Confirm

RCm51

51n

n=0: Disable

1: Enable

Change

WCm83n

OK

m=0 to 3: Codes 1 to 4

Confirm

RCm83

83n

n=0: Disable

1: Enable

Change

WCm84n

OK

m=0 to 3: Codes 1 to 4

Confirm

RCm84

84n

n=0: Forward

1: Reverse

Change

WCm85nn

OK

m=0 to 3: Codes 1 to 4 00, 02,

Confirm

RCm85

85nn

nn=01 to 32

03, 04,

: Effective digits

05, 09,

Change

WCm86nn

OK

m=0 to 3: Codes 1 to 4 14

Confirm

RCm86

86nn

nn=01 to 32

: Starting digit

Change

WCm81n

OK

m=0 to 3: Codes 1 to 4 00, 02,

Confirm

RCm81

81n

n=0: Disable

03, 04,

1: Enable

05, 07,

Change

WCm82n

OK

m=0 to 3: Codes 1 to 4 14

Confirm

RCm82

82n

n=0: Forward

1: Reverse

EAN/UPC(A•E)
Reading JAN 13
digits

EAN/UPC(A•E)
No. of UPC-A
output digits

EAN/UPC(A•E)
Adding “0” to UPC-
E system code

CODE128 Checking
double character
start pattern

➮ See p. 32.

Setting max. code
length output
function

Setting direction for
max. code length
output

Setting effective
digits for max. code
length output

Setting starting digit
for max. code
length output

Setting label
orientation speci-
fied reading

Setting orientation
for orientation-
specified reading