KEYENCE BL-700 Series User Manual

Page 111

Advertising
background image

97

Chapter 5 Serial Communication

5

Function

Command being

Response

Description

Error

sent

code

Change

WP12n

OK

n=0: Single label

00, 02,

Confirm

RP12

12n

1: Multi label 1

05, 08,

2: Multi label 2

14

3: Multi label 3

Change

WP13n

OK

N=0: Sends data after

00, 02,

Confirm

RP13

13n

reading

05, 07,

1: Sends after timing 14

input turns off

Change

WP41nnn

OK

nnn=001 to 225

00, 02,

Confirm

RP41

41nnn

(by 100 ms step)

05, 09,

14

Change

WP43nnn

OK

nnn=001 to 225

Confirm

RP43

43nnn

Change

WP10n

OK

n=0: No addition

00, 02,

Confirm

RP10

10n

1: Add

05, 07,

14

Change

WP11n

OK

n=0: No addition

Confirm

RP11

11n

1: Add

Change

WP14n

OK

n=0: No addition

Confirm

RP14

14n

1: Add

Change

WP17n

OK

n=0: No addition

Confirm

RP17

17n

1: Add

Change

WP55hhh...

OK

hhh ... = Reading error

00, 02,

Confirm

RP55

55hhh...

code (within 8 characters) 05, 06,

10, 12,

14

Setting Reading Mode/Data Addition Functions

To set the reading error code, send the following command:

Example 1

Set the reading error code to “BR”.

WP554252
* B = 42h, R = 52h

Example 2

Set no reading error code.
WP55FF

Tips

Setting reading
mode

Setting data send
timing

Setting repeat-read
time in multi label
reading mode 1 or 2

Setting decoding
match count

Setting decoding
match count in
additional
information

Setting scans in
additional
information

Note: Effective only
when No. of
decodings are added.

Setting label
orientation in
additional information

Setting code type in
additional information

Setting reading
error code

* Specify the charac-
ters in HEX (hexadeci-
mal) code.
* If the reading error
code is not specified,
hhh... = FF.

B R