KEYENCE BL-700 Series User Manual

Page 74

Advertising
background image

Chapter 4 Installing the Setup Software

60

4

■ When using the PLC link
To enable the "Use PLC", set each item as follows:

•

Set “Connected PLC”, “DM head address” and “Station No.”.
To set “DM head address”, enter a value (0000 to 9900) using the keyboard.

•

To send a trigger signal to the BL series when the PLC link is enabled, set “PLC
trigger area”.

•

To use “File Register”, set “File Register” to “Enable”. When “File Register” is
enabled, the following screen appears. The “File Register” can be used with the
Mitsubishi MELSEC-A series only.

Enter the block number (000 to 255) of the file register using the keyboard.

•

PLC link

➮ P.106

•

PLC trigger area

➮ P.113 to 115

•

DM head address

➮ P.111

•

File register

➮ P.107

The setting of the station
number is not displayed
when “KV Series” is selected.

The setting of the file register
is displayed only when
“MELSEC-A” is selected.

Tips