Appendix B BL-U1 Specifications*

Model

BL-U1

Power supply for bar code reader

5 VDC±5% (1.5 A)

Power supply for sensor

12 V ±10% (300 mA)

Input rating

8.5 to 30 VDC, 10 mA max.

Max. OFF current

0.5 mA

Output type

NPN open-collector

Rated load

30 VDC, 100 mA

Leakage current (at OFF)

0.1 mA max.

Residual voltage (at ON)

1 V max.

Interface

RS-232C, RS-422A, RS-485 multidrop

(Up to 31 units can be connected.

Max. cable extension: 1.2 km)

Ambient temperature

0 to 50°C (32 to 122°F), No freezing

Relative humidity

35 to 85%, No condensation

Ambient atmosphere

No dust, no corrosive gas

Vibration

10 to 55 Hz, 1.5 mm double amplitude in X,

Y and Z directions, 2 hours respectively

Noise immunity

1000 V p-p, 1 µs (Power line)

Power supply voltage

100 to 240 VAC (50/60 Hz)

Current consumption

40 VA (100 VAC), 50 VA (240 VAC)

Weight

Approx. 615 g (including cable)