BL-740/741

Unit: mm

Bar code type

Narrow bar width

Reading

Max. readable

distance

label width

A

CODE39

0.25

360 to 440

330

B

CODE39

0.32

360 to 490

350

C

CODE39

0.5

330 to 550

430

D

CODE39

1

230 to 650

510

E

UPC/EAN1x

1 time

150 to 750

600

Note 1: The readable label width means a bar code length including the right and
left margins (quiet zones) of a bar code.

Note: 2 Even if a bar code is within the above reading range, it may not be read
depending on the bar code quality. Set the optimum reading position based on
enough reading tests.

Note 3: Normally, the reading distance should be set to 230 mm (focal length). In
this case, the maximum readable label width is 215 mm (when the narrow bar
width is 0.19 mm or more).

E

360~440

A 360~490

B 330~550

C 230~650

D 150~750

400

300 340 330 350 430 510 600

0

100

200

300

400

500

600

700

800

300

200

100

0

100

200

300

Reading distance
(mm)

(Focal length)

Readable label width
(mm)

(Measuring conditions)
• The KEYENCE standard

bar code is used.

• Ratio of thin bar to thick

bar = 1:2.5

• Skew: 0°
• Pitch: 0°
• Tilt: 0°