5 connecting rs-232c – KEYENCE BL-700 Series User Manual

Page 25

Advertising
background image

Chapter 2 Connection and Installation

2

11

Connecting OK/NG output
The OK/NG output is used to differentiate between acceptable and unacceptable
results based on the comparison with the preset data, and to indicate whether or
not the BL-700 series successfully read bar codes.

➮ See P.44.

The OK/NG output is an open-collector output.

I/O circuit diagram
• Input circuit diagram

• Output circuit diagram

2.2.5 Connecting RS-232C

Pin assignment

COM

OK

NG

Load

Load

+

*Rated load: 30 V max. (100 mA)

TIM

2.4

kΩ

3.3 kΩ

Internal circuit

Load

OK/NG

COM

+

Internal circuit

13

1

25

14

D-sub 25-pin (female)
DCE specification (defined as terminal)
M2.6 screw (female)

Pin No.

Symbol

Function

Signal direction

1

FG

Frame ground

2

SD (TXD)

Sends RS-232C data

Output

3

RD (RXD)

Receives RS-232C data

Input

4

RS (RTS)

Ready to send RS-232C data

Output

(always ON)

5

CS (CTS)

Request to send RS-232C data

Input

6

DR (DSR)

Connected to pin No. 20 inside.

Input

7

GND (SG)

Signal ground

20

ER (DTR)

Connected to pin No. 6 inside.

Output

Advertising