KEYENCE BL-700 Series User Manual

Page 75

Advertising
background image

61

Chapter 4 Installing the Setup Software

4

Code Setup (Bar code setting)

Set the readout digits, detail data and special functions for each code type.

1. Set the code.

Set the type and number of digits of the bar codes to be read in codes 1 to 4.
If four different types of codes are specified in 1 to 4, the BL-700 can read 4
types of bar codes without changing the settings.

2. Click [Details] to set “Send start/stop character” and “Check digit test”.

3. Click [Options] to set “Fixed-digit output function” and “Label orientation func-

tion” (

➮ see P.69).

*

Be sure to set the ITF digits to an even number.

*

For UPC/EAN, set whether each of the 13-digit EAN, 8-digit EAN and UPC-E is
enabled to read.

*

CDE128 varies depending on the type of the start/stop character (CODE-A to
CODE-C)

CODE-A/B: 1 to 31
CODE-C: 1 to 64

The start/stop character and check digit are not included in the number of digits.
Also, FUN 1 to 4 (function codes), SHIFT and CODE-A to CODE-C are not
included in the number of digits.

Advertising