3 device assignment – KEYENCE BL-700 Series User Manual

Page 123

Advertising
background image

109

Chapter 6 PCL Link

6

6.3

Device Assignment

The data areas used to control the BL-700 are provided in the PLC’s internal
memory (D areas or DM areas).
When a device head address is specified on the “PLC SETUP” screen in the BL-
700 setup software, the device numbers are automatically assigned based on the
specified head address.

Data memory head address

[Specified head address] +00 indicates the area where the bar code data is stored.
[Specified head address] +01 to +03 are reserved areas and cannot be assigned
for the bar code data.
[Specified head address] +04 to +06 are the areas used by the PLC to send a
reading trigger to the BL-700. The method for using the areas varies depending on
the BL-700 scan method, “Level signal trigger” or “One-shot signal trigger”. These
areas are not assigned if you set “Reading trigger input area” to “Disable” in the
BL-700 setup software. (In this case, these areas can be used for other purposes.)

When using the BL-700 in multi-label read mode 3, addresses +00 to +03 are used
as the data memory head addresses for Codes 1 to 4, respectively. Data is not
stored in the areas for which the code type is not set.

Address

Description

Reference page

+00

Data memory head address for Code 1

P.111

+01

Reserved area for Code 2

P.111

+02

Reserved area for Code 3

P.111

+03

Reserved area for Code 4

P.111

+04

Reading trigger area

P.111 to 113

+05

Reading trigger response area
* Only when “Level signal trigger” is selected.

+06

One-shot trigger time setup area
* Only when “One-shot signal trigger” is selected.