Chapter 2 Connection and Installation

2

7

2.1.3 Wiring I/O

Trigger input
The trigger input is used to signal the BL-700 to start reading (start laser emission).
The trigger input is a non-voltage input (TTL input is also available with negative
logic).

OK/NG output
This output signals whether the readout data is the same as the preset data. When
no preset data has been entered, the signal indicates bar code read status. It is an
NPN open-collector output.

➮ See P. 44

2.1.4 RS-232C connection

Wire the RS-232C as indicated below when connecting the BL-700 to a PC.

Connecting the computer with 25-pin

GND

TIM

1

5

5 VDC

10 kΩ

4.7
kΩ

Internal circuit

BL-700

Contact or
solid-state

3

2

8

7

5

9

BL-700

SD

CS

RS

GND

+5V

PC

2

3

4

7

6

5

20

SD

RD

RD

RS

CS

SG

DR

ER

D-sub 25-pin (male)

M2.6 screw

D-sub 9-pin (male)

# 4-40 screw

GND

OK/NG

4/6

5

Load

BL-700

10 kΩ

* Rated load: 24 VDC
(30 mA) max.

+

Internal circuit

Advertising