Chapter 3 Functions for Reading Operation
32
3
3.1.2 Data-send mode
In the single label read mode only, you can select from the two data send modes
(OK/NG output on trigger) described below: In the multi-label read mode, you can
only select the “send after reading” mode.
•
Send after read
The unit outputs the communication and OK/NG signals after a successful read
(trigger output turns on as many times as the preset decode count). This is the
same operation as in the time chart described in “3.1.1 Scanning method”. Nor-
mally, this is the method you should use.
•
Send at trigger input
The unit outputs the communication and OK/NG signal when the trigger input turns
off (or the preset input time has passed if one-shot signal trigger is selected).
OK/NG
NG
<Succeed to read>
<Fail to read>
Trigger input
Bar code
Laser beams
Communication time
OK/NG output