KEYENCE BL-700 Series User Manual

Page 115

Advertising
background image

101

Chapter 5 Serial Communication

5

■ Setting communication parameters 2 (only when PLC link is used)

PLC link model

Function

Command

Response Description

Change

WP36n

OK

n = 0: PLC link disabled

n = 1: SYSNAC-C

n = 2: MELSEC-A

n = 3: KV

n = 4: MELSEC-A (File
register is used.)

Confirm

36n

Change

OK

n = 0: Disable

n = 1: Enable

Confirm

RP37

37n

WP37n

Change

WP45nn

OK

Confirm

RP45

45nn

RP36

nn = 00 to 99

(0000 to 9900)

Change

WP47nn

OK

nn = 00 to 31

Confirm

RP47

47nn

Change

WP46nnn

OK

nnn = 000 to 255

Confirm

RP46

46nnn

Error code

00, 02,

05, 07,

14

00, 02,

05, 09,

14

Trigger input
through PLC
link

DM head
address

PLC / station
number

File register
block number

Function

Command

Response Description

hh = Partition mark
(1 character)

* Specify the mark in

HEX (hexadecimal)
code.

Error code

00, 02,

05, 06,

10, 12,

14

■ Setting communication strings

Setting partition
mark when
additional
information is
used.

Change

WP50hh

OK

Confirm

RP50

50hh

hhh = Intermediate
delimiter (Up to 5
characters)

* Specify the mark in

HEX (hexadecimal)
code.

* To set no intermediate

delimiter, hhh = FF.

Setting interme-
diate delimiter
when multi label
reading mode 2
or 3 is used.

Change

WP54hhh... OK

RP54

54hhh...

Confirm