Chapter 6 PLC Link

104

6

6.1

PLC Link

The PLC link enables read data to be directly stored in the internal memory of a
PLC (programmable logic controller).

Since the BL-700 directly controls the PLC’s memory, no program is required for
data communication, resulting in a reduced number of programming steps.

As compared with the serial communication using a computer, the PLC link in-
volves the following limitations:

The BL-700 settings cannot be changed because the PLC link cannot send a
command to the BL-700. However, the PLC link provides a reading control
address to start/end reading.

The PLC link cannot start the test mode.

6.1.1 List of PLCs used for PLC link

KEYENCE

(Built-in CPU port)

KV series

KV-10/16/24/40/80
KV-300*

(Serial interface module)

KV-L2*

Mitsubishi

(Built-in CPU port)

MELSEC-A series

A2CCPU24
A2CCPU24-PRF

(Calculator link unit)

AJ71C24
AJ71C24-Sx
AJ71UC24
A0J2-C214-S1
A1SJ71(U)C24-R2/PRF/R4

OMRON

(Built-in CPU port)

SYSMAC-C series

C20H/28H/40H/60H
C200HS(CPU21/23/31/33)
C200HE(CPU42)
C200HG(CPU43/63)
C200HX(CPU44/64)

(High-order link unit)

C200H-LK201(-V1)
C500-LK203
C500-LK201-V1
C120-LK201-V1
C200H-LK202(-V1)
C120-LK202-V1

(Communication board)

C200HW-COM02
C200HW-COM03
C200HW-COM04
C200HW-COM05
C200HW-COM06

OMRON

(Built-in CPU port)

SYSMAC-CQM1 series

CQM1(CPU21/41/42/43/44)

OMRON

(Built-in CPU port)

SYSMAC-CV series

CV500
CV1000
CV-M1

(High-order link unit)

CV500-LK201

Note: KV-300 and KV-L2 are not available in Europe.