11 select the scaling info menu option, There are three scaling options – YSI 6000UPG User Manual

Page 83

Advertising
background image

5-11

Select the Scaling Info menu option

+------------------------------------------------------------------------------+
¦

Sonde

File

Setup

Real-Time

Exit

YSI PC6000

¦

¦------------------------------------------------------------------------------¦
¦

¦

¦

¦

¦

¦

¦

+--------------------------------------------------------+

¦

¦

¦

Filename:

SRUNS62O.DAT

¦

¦

¦

¦--------------------------------------------------------¦

¦

¦

¦

MODIFY

¦

VIEW

¦

SYSTEM

¦

¦

¦

¦------------------+------------------+------------------¦

¦

¦

¦

Parameters...

¦

Header

¦

Print Report

¦

¦

¦

¦

Control Info... ¦

Report

¦

Print Plot

¦

¦

¦

¦

Scaling Info... ¦

Plot

¦

Definitions... ¦

¦

¦

¦

¦

Statistics

¦

Export

¦

¦

¦

+--------------------------------------------------------+

¦

¦

¦

¦

¦

¦

¦

¦

¦

¦

¦

¦

¦

¦------------------------------------------------------------------------------¦
¦

View or change scaling technique, minima, and maxima

¦

+------------------------------------------------------------------------------+

There are three scaling options.

+------------------------------------------------------------------------------+
¦

Sonde

File

Setup

Real-Time

Exit

YSI PC6000

¦

¦------------------------------------------------------------------------------¦
¦

Scaling technique: automatic

¦

¦

Copy default to manual

¦

¦

Copy automatic to manual

Default

Manual

Automatic

¦

¦

Scaling

Scaling

Scaling

¦

¦

Parameter

Units

Minimum Maximum

Minimum Maximum

Minimum Maximum ¦

¦

------------

--------

------- -------

------- -------

------- ------- ¦

¦

Temperature

C

-5

45

-5

45

-5

45

¦

¦

Specific Cond mS/cm

0

235

0

235

0

235

¦

¦

DO

mg/L

0

20

0

20

0

20

¦

¦

pH

2

14

2

14

2

14

¦

¦

ORP

mV

-1000

1000

-1000

1000

-1000

1000

¦

¦

Battery

volts

0

30

0

30

0

30

¦

¦

Turbidity

NTU

0

1000

0

1000

0

1000

¦

¦

¦

¦

¦

¦

¦

¦

¦

¦

¦

¦

¦

¦------------------------------------------------------------------------------¦
¦

Select scaling technique (default, manual, automatic)

¦

+------------------------------------------------------------------------------+

Default scaling offers fixed limits. These limits correspond to the range of each parameter as
defined by the sensor specifications, so your plot will always fit within these limits.

Manual scaling allows you to enter custom limits for each parameter.

Automatic scaling. The computer scans the data file and determines its limits, then displays those
limits on the plot.

NOTE: When entering a scaling technique, you need only type the first letter of the desired
technique and press Enter. PC6000 will fill in the rest.