3 mii interface, Mii interface, Table 13: special/unused mii interface signals – BECKHOFF EtherCAT Technology Section I User Manual

Page 41

Advertising
background image

Ethernet Physical Layer

Slave Controller

– Technology

I-21

5.3

MII Interface

Refer to Section III for ESC specific MII information.

If an ESC MII interface is not used, LINK_MII has to be tied to a logic value which indicates no link,
and RX_CLK, RXD, RX_ER, and especially RX_DV have to be tied to GND. The TX outputs can be
left unconnected, unless they are used for ESC configuration.

Table 13: Special/Unused MII Interface signals

Signal

Direction
at PHY

Description

TX_CLK

OUT

ESC20:

TX_CLK of one PHY is used as clock source, TX_CLK of other
PHY is unused, leave open.

ESC dependent (e.g., IP Core):

TX_CLK is optionally used for automatic TX Shift compensation.

Other Beckhoff ESCs:

Unused, leave unconnected.

COL

OUT

Collision detected.
ESC20:

Connected, but not used.

Other Beckhoff ESCs:

Unused. Leave unconnected.

CRS

OUT

Carrier sense.
ESC20:

Connected, but not used.

Other Beckhoff ESCs:

Unused. Leave unconnected

TX_ER

IN

Transmit error.
ESC20:

Connected, always driven low.

Other Beckhoff ESCs:

Connect to GND.

For more details about the MII interface, refer to IEEE Standard 802.3 (Clause 22), available from the
IEEE.