i.7

Troubleshooting

NOTICE

Refer to the iQpump Micro User Manual TOEP YAIQPM 03 for complete information on Troubleshooting causes and
solutions.
The iQpump Micro User Manual is posted on the Yaskawa website, www.yaskawa.com.

u

Fault Detection

Note:

Digital operator display text is represented in the tables below using standard font for both LCD displays and LED displays. When using

the standard LED operator, however, display text will appear in 7-segment LED (ex: “

”). When the LED fault display differs from the

LCD display, the LED display text will be shown in parentheses under the LCD display text.

n

Fault Displays

Digital Operator

Display

Fault Name

AJF

Anti-Jam Fault

(AJF)

<1>

Anti-Jam Fault

bUS

Option Communication Error
• The connection was lost after establishing initial communication.
• Only detected when the run command frequency reference is assigned to an option card.

CE

MEMOBUS/Modbus Communication Error
Control data was not received for the CE detection time set to H5-09.

CPF02

A/D Conversion Error
An A/D conversion error or control circuit error occurred.

CPF03

PWM Data Error
There is a problem with the PWM data.

CPF06

<1>

EEPROM Memory Data Error
Error in the data saved to EEPROM

CPF07

Terminal Board Communications Error
A communication error occurred at the terminal board.

CPF08

EEPROM Serial Communication Fault
EEPROM communications are not functioning properly.

CPF11

RAM Fault

CPF12

FLASH Memory Fault
Problem with the ROM (FLASH memory).

CPF13

Watchdog Circuit Exception
Self-diagnostics problem.

CPF14

Control Circuit Fault
CPU error (CPU operates incorrectly due to noise, etc.)

CPF16

Clock Fault
Standard clock error.

CPF17

Timing Fault
A timing error occurred during an internal process.

CPF18

Control Circuit Fault
CPU error. Non-Maskable Interrupt (An unusual interrupt was triggered by noise, etc.)

CPF19

Control Circuit Fault
CPU error (Manual reset due to noise, etc.)

CPF20 or CPF21

One of the following faults occurred: RAM fault, FLASH memory error, watchdog circuit exception, clock error