Display

Fault Name

CPF22

A/D Conversion Fault
A/D conversion error.

CPF23

PWM Feedback Fault

CPF24

<1>

Drive Unit Signal Fault
The drive capacity cannot be detected correctly (drive capacity is checked when the drive is powered up).

CPF25

Terminal Board Not Connected

CPF26 to CPF35

CPF40 to CPF43

Control Circuit Error
CPU error

E5

SI-T3 Watchdog Timer Error
The watchdog timed out.

EF0

Option Card External Fault
An external fault condition is present.

EF1

Pump Fault (input terminal S1)
External fault at multi-function input terminal S1.

EF2

Pump Fault (input terminal S2)
External fault at multi-function input terminal S2.

EF3

Pump Fault (input terminal S3)
External fault at multi-function input terminal S3.

EF4

Pump Fault (input terminal S4)
External fault at multi-function input terminal S4.

EF5

Pump Fault (input terminal S5)
External fault at multi-function input terminal S5.

EF6

Pump Fault (input terminal S6)
External fault at multi-function input terminal S6.

EF7

Pump Fault (input terminal S7)
External fault at multi-function input terminal S7.

Err

EEPROM Write Error

Data cannot be written to the EEPROM

FAn

Internal Cooling Fan Failure

FDBKL Wire Break

(FDB-L)

PID Feedback Loss
The analog input programmed for PID feedback has risen above 21 mA or fallen below 3 mA.

GF

Ground Fault
• A current short to ground exceeded 50% of rated current on the output side of the drive.
• Setting L8-09 to 1 enables ground fault detection in models 2V0020 to 2V0069 and 4V0011 to 4V0038.

HFB

High Feedback
The feedback signal is too high.

HWL

(HIH20)

High Water Level
The “High Water Level” digital input is active (H1-0o = 90).

LF

Output Phase Loss
• Phase loss on the output side of the drive.
• Setting L8-07 to 1 or 2 enables Phase Loss Detection.

LF2

Output Current Imbalance
One or more of the phases in the output current are lost.

LFB

Low Feedback
The feedback signal is too low.

LOP

Loss of Prime
The pump has lost its prime.

i.7 Troubleshooting

YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide

79