No.

Name

Description

C3-03

Slip Compensation

Limit

Sets an upper limit for the slip

compensation function as a percentage of

motor rated slip for motor 1 (E2-02).

C3-04

Slip Compensation

Selection during

Regeneration

0: Disabled

1: Enabled above 6 Hz

C4-01

Torque Compensation

Gain

Sets the gain for the automatic torque

(voltage) boost function and helps to

produce better starting torque. Used for

motor 1.

C4-02

Torque Compensation

Primary Delay Time 1 Sets the torque compensation filter time.

C6-02

Carrier Frequency

Selection

1: 2.0 kHz

2: 5.0 kHz (4.0 kHz)

3: 8.0 kHz (6.0 kHz)

4: 10.0 kHz (8.0 kHz)

5: 12.5 kHz (10.0 kHz)

6: 15.0 kHz (12.0 kHz)

7: Swing PWM1 (Audible sound 1)

8: Swing PWM2 (Audible sound 2)

9: Swing PWM3 (Audible sound 3)

A: Swing PWM4 (Audible sound 4)

B: Leakage Current Rejection PWM

C to E: No setting possible

F: User-defined (determined by C6-03

through C6-05)

C6-03

Carrier Frequency

Upper Limit

Determines the upper and lower limits for

the carrier frequency.

C6-04

Carrier Frequency

Lower Limit

C6-05

Carrier Frequency

Proportional Gain

d1-01 to

d1-16

Frequency Reference 1

to 16

Sets the frequency reference for the drive.

Setting units are determined by parameter

o1-03.

d1-17

Jog Frequency

Reference

Sets the Jog frequency reference. Setting

units are determined by parameter o1-03.

d2-01

Frequency Reference

Upper Limit

Sets the frequency reference upper limit as

a percentage of the maximum output

frequency.

d2-02

Frequency Reference

Lower Limit

Sets the frequency reference lower limit as

a percentage of the maximum output

frequency.

d2-03

Master Speed

Reference Lower Limit

Sets the lower limit for frequency

references from analog inputs as a

percentage of the maximum output

frequency.

d3-01

Jump Frequency 1

Eliminates problems with resonant

vibration of the motor/machine by avoiding

continuous operation in predefined

frequency ranges. The drive accelerates and

decelerates the motor through the

prohibited frequency ranges.

d3-02

Jump Frequency 2

d3-03

Jump Frequency 3

d3-04

Jump Frequency Width

Sets the dead-band width around each

selected prohibited frequency reference

point.

d4-01

Frequency Reference

Hold Function

Selection

0: Disabled. Drive starts from zero when

the power is switched on.

1: Enabled. At power up, the drive starts the

motor at the Hold frequency that was saved.

d4-03

Frequency Reference

Bias Step (Up/Down 2)

Sets the bias added to the frequency

reference when the Up 2 and Down 2 digital

inputs are enabled (H1-oo = 75, 76).

d4-05

Frequency Reference

Bias Operation Mode

Selection (Up/Down 2)

0: Bias value is held if no input Up 2 or

Down 2 is active.

1: When the Up 2 reference and Down 2

reference are both on or both off, the applied

bias becomes 0. The specified accel/decel

times are used for acceleration or

deceleration.

No.

Name

Description

d4-06

Frequency Reference

Bias (Up/Down 2)

The Up/Down 2 bias value is saved in d4-06

when the frequency reference is not input

by the digital operator. Set as a percentage

of the maximum output frequency.

d4-07

Analog Frequency

Reference Fluctuation

Limit (Up/Down 2)

Limits how much the frequency reference

is allowed to change while an input terminal

set for Up 2 or Down 2 is enabled.

d4-08

Frequency Reference

Bias Upper Limit (Up/

Down 2)

Sets the upper limit for the bias and the

value that can be saved in d4-06. Set as a

percentage of the maximum output

frequency.

d4-09

Frequency Reference

Bias Lower Limit (Up/

Down 2)

Sets the lower limit for the bias and the

value that can be saved in d4-06. Set as a

percentage of the maximum output

frequency.

d4-10

Up/Down Frequency

Reference Limit

Selection

0: The lower limit is determined by d2-02

or an analog input.

1: The lower limit is determined by d2-02.

E1-01

Input Voltage Setting

This parameter must be set to the power

supply voltage.

WARNING!Electrical Shock Hazard.

Drive input voltage (not motor voltage)

must be set in E1-01 for the protective

features of the drive to function properly.

Failure to do so may result in equipment

damage and/or death or personal injury.

E1-03

V/f Pattern Selection

0: 50 Hz, Constant torque 1

1: 60 Hz, Constant torque 2

2: 60 Hz, Constant torque 3 (50 Hz base)

3: 72 Hz, Constant torque 4 (60 Hz base)

4: 50 Hz, Variable torque 1

5: 50 Hz, Variable torque 2

6: 60 Hz, Variable torque 3

7: 60 Hz, Variable torque 4

8: 50 Hz, High starting torque 1

9: 50 Hz, High starting torque 2

A: 60 Hz, High starting torque 3

B: 60 Hz, High starting torque 4

C: 90 Hz (60 Hz base)

D: 120 Hz (60 Hz base)

E: 180 Hz (60 Hz base)

F: Custom V/f, E1-04 through E1-13

settings define the V/f pattern

E1-04

Maximum Output

Frequency

These parameters are only applicable when

E1-03 is set to F.

To set linear V/f characteristics, set the

same values for E1-07 and E1-09.

In this case, the setting for E1-08 will be

disregarded. Ensure that the four

frequencies are set according to these rules:

E1-09 ≤ E1-07 < E1-06 ≤ E1-11 ≤ E1-04

Setting E1-11 to 0 disables both E1-11 and

E1-12 and the above conditions do not

apply.

Output Voltage (V)

Frequency (Hz)

E1-05
E1-12

E1-13

E1-08

E1-10

E1-09

E1-07 E1-06 E1-11 E1-04

E1-05

Maximum Voltage

E1-06

Base Frequency

E1-07

Middle Output

Frequency

E1-08

Middle Output

Frequency Voltage

E1-09

Minimum Output

Frequency

E1-10

Minimum Output

Frequency Voltage

E1-11

Middle Output

Frequency 2

E1-12

Middle Output

Frequency Voltage 2

E1-13

Base Voltage

E2-01

Motor Rated Current

Sets the motor nameplate full load current

in amps. Automatically set during

Auto-Tuning.

E2-02

Motor Rated Slip

Sets the motor rated slip. Automatically set

during Auto-Tuning.

E2-03

Motor No-Load

Current

Sets the no-load current for the motor.

Automatically set during Auto-Tuning.

i.9 Parameter Table