o2-05

Frequency Reference

Setting Method

Selection

0: ENTER key must be pressed to enter

a frequency reference.

1: ENTER key is not required. The

frequency reference can be adjusted using

the up and down arrow keys only.

o2-06

Operation Selection

when Digital Operator

is Disconnected

0: The drive continues operating if the

digital operator is disconnected.

1: An oPr fault is triggered and the motor

coasts to stop.

o2-07

Motor Direction at

Power Up when Using

Operator

This parameter requires assigning drive

operation to the digital operator.

0: Forward

1: Reverse

o2-30

Monitor Position Save

Saves the monitor position and Home

Screen quick monitor selection.

0: Disabled

1: Enabled

o3-01

Copy Function

Selection

0: No action

1: Read parameters from the drive, saving

them onto the digital operator.

2: Copy parameters from the digital

operator, writing them to the drive.

3: Verify parameter settings on the drive to

check if they match the data saved on the

operator.

o3-02

Copy Allowed

Selection

0: Read operation prohibited

1: Read operation allowed

o4-01

Cumulative Operation

Time Setting

Sets the value for the cumulative operation

time of the drive in units of 10 h.

o4-02

Cumulative Operation

Time Selection

0: Logs power-on time

1: Logs operation time when the drive

output is active (output operation time).

o4-03

Cooling Fan Operation

Time Setting

Sets the value of the fan operation time

monitor U4-03 in units of 10 h.

o4-05

Capacitor Maintenance

Setting

Sets the value of the Maintenance Monitor

for the capacitors. See U4-05 to check when

the capacitors may need to be replaced.

o4-07

DC Bus Pre-Charge

Relay Maintenance

Setting

Sets the value of the Maintenance Monitor

for the soft charge bypass relay. See U4-06

to check when the bypass relay may need to

be replaced.

o4-09

IGBT Maintenance

Setting

Sets the value of the Maintenance Monitor

for the IGBTs. See U4-07 for IGBT

replacement times.

o4-11

U2, U3 Initialization

0: U2-oo and U3-oo monitor data is

not reset when the drive is initialized

(A1-03).

1: U2-oo and U3-oo monitor data is

reset when the drive is initialized (A1-03).

o4-12

kWh Monitor

Initialization

0: U4-10 and U4-11 monitor data is not

reset when the drive is initialized (A1-03).

1: U4-10 and U4-11 monitor data is reset

when the drive is initialized (A1-03).

o4-13

Number of Run

Commands Counter

Initialization

0: Number of Run commands counter is

not reset when the drive is initialized

(A1-03).

1: Number of Run commands counter is

reset when the drive is initialized (A1-03).

o4-17

Set/Reset Real-Time

Clock

0: - -

1: Set

2: Reset

o4-20

Time Display Format

0: 12-hour

1: 24-hour

P1-01

Pump Mode

0: Drive only

3: MEMOBUS network

No.

Name

Description

P1-02

System Units

0: No unit

1: PSI: Pounds per square inch

2: Pa: Pascals

3: Bar: Bar

4: ”WC: Inch of water

5: ”Hg: Inch of Mercury

6: ft: feet

7: m: meters

8: °F: Degrees Fahrenheit

9: °C: Degrees Celsius

10: Percent

P1-03

Feedback Device

Scaling

Sets the scaling of feedback device in user-

set units.

P1-04

Start / Draw Down

Level

The system starts when the feedback level

drops below the start level for the time set

in P1-05. This level also specifies the wake-

up level when the drive is in Sleep Mode.

Note: When PID operates in reverse mode,

the system will start when the feedback has

risen above the start level for the time set to

P1-05.

P1-05

Start Level Delay Time

The system starts when the feedback level

drops below the start level for the time set

in this parameter.

P1-06

Minimum Pump Speed

Minimum frequency at which the drive will

run. Applies to both HAND and AUTO

Modes.

Note: For minimum pump frequency, the

drive will use the highest setting from

among P1-06, P4-12 (Thrust Bearing

Frequency), or d2-02 (Reference Lower

Limit).

P1-07

Minimum Pump Speed

Units

0: Hz

1: RPM

Note: Changing this parameter will reset

the P1-06 default value.

P1-08

Low Feedback Level

Sets the lower detection level for the PID

feedback.

P1-09

Low Feedback Level

Fault Delay Time

Sets the amount of delay time from when

the low feedback is detected until the drive

faults on an “LFB Low Feedback” fault.

Note: This parameter is effective only when

P1-10 is set to 0 (Fault).

P1-10

Low Feedback

Selection

0: Fault

1: Alarm

2: Digital out only

P1-11

High Feedback Level

Sets the upper detection level for the PID

feedback.

Note: When P1-03 is set to 3, parameter

P9-18 uses the value set here to calculate

quick de-stage feedback level.

P1-12

High Feedback Level

Fault Delay Time

Sets the amount of delay time from when

the high feedback is detected until the drive

faults on a “HFB High Feedback” fault.

Note: This parameter is effective only when

P1-13 is set to 0 (Fault (and digital out)).

P1-13

High Feedback

Selection

0: Fault

1: Alarm

2: Digital out only

P1-14

Hysteresis Level

Sets the hysteresis level used for low and

high level feedback detection.

P1-15

Maximum Setpoint

Difference

Sets the level that the difference between

the setpoint and the feedback must exceed

for the time set in P1-16 to trigger the drive

response set in P1-17.

P1-16

Not Maintaining

Setpoint Time

Sets the delay time before a “Setpoint Not

Met” condition occurs. The pump

protection criteria set in P1-15 must be met

before the timer will start.

P1-17

Not Maintaining

Setpoint Selection

0: Fault

1: Alarm

2: Digital out only

i.9 Parameter Table