Yaskawa SmartTrac AC1 User Manual

Page 24

Advertising
background image


SMART TRAC AC1

4-4

••

Smart Trac AC1 Installation Technical Manual TM 3554-000

Never allow wire leads to contact metal surfaces. Short-circuit may
result.

Never connect power factor correction capacitors or noise filters to
Smart Trac AC1 output.

Table 2. Terminal screws, connectors and clamping torque by wire size

Wire
Size
(AWG)

Wire
Size
(mm

2

)

Terminal
Screw

Closed-
Loop
Connector

Clamping
Torque
Steel,
lb-in

Clamping
Torque
Steel, N-m

Clamping
Torque
Copper,
lb-in

Clamping
Torque
Copper,
lb-in

20

0.50

M3.5

1.25-3.5

7.8

0.9

7.0

0.8

18

0.75

M4

1.25-4

13.0

1.5

10.4

1.2

16

1.25

M4

1.25-4

13.0

1.5

10.4

1.2

M4

2-4

13.0

1.5

10.4

1.2

14

2

M5

2-5

26.1

20.9

3.1

2.4

M4

3.5-4

13.0

1.5

10.4

1.2

12

3.5

M5

3.5-5

26.1

20.9

3.1

2.4

M4

5.5-4

13.0

1.5

10.4

1.2

10

5.5

M5

5.5-5

26.1

20.9

3.1

2.4

M5

8-5

26.1

20.9

3.1

2.4

8

8

M6

8-6

40.9

34.8

4.8

4.1

6

14

M6

14-6

40.9

34.8

4.8

4.1

4

22

M8

22-8

100.0

82.6

11.7

10.7

M8

38-8

100.0

82.6

11.7

10.7

2

38

M10

38-10

182.6

156.5

21.4

18.4

1/0

60

M10

60-10

182.6

156.5

21.4

18.4

3/0

80

M10

80-10

182.6

156.5

21.4

18.4

M10

100-10

182.6

156.5

21.4

18.4

4/0

100

M12

100-12

313.0

191.3

36.7

23.1

MCM300

150

M12

150-12

313.0

191.3

36.7

23.1

MCM400

200

M12

200-12

313.0

191.3

36.7

23.1

MCM650

325

M12

325-12

313.0

191.3

36.7

23.1

M16

325-16

313.0

191.3

36.7

23.1

Advertising