Yaskawa SmartTrac AC1 User Manual
Page 46
 
 
 
SMART TRAC AC1
4-26
••
Smart Trac AC1 Installation Technical Manual TM 3554-000
Auto-Tuning Faults and Corrective Actions
Digital Operator Display
Description
Corrective Action
Tune aborted-Motor Speed
Torque reference exceeded 
100% during auto-tuning. 
Uncouple motor from load.
Increase acceleration time 
(C1-01). 
Check input data, especially 
the encoder PPR 
(parameter F1-01). 
Tune aborted-Over Load 
(Displayed after completion 
of tuning) 
Torque reference exceeded 
20% during auto-tuning 
Uncouple motor from load.
Increase acceleration time 
(C1-01) 
Check input data, especially 
the encoder PPR (F1-01). 
Tune aborted-Minor Fault: 
XXX 
A minor drive fault occurred. Check for specific minor
Power Conversion Unit fault 
indicated by "XXX." (See 
"Smart Trac Fault Codes 
Technical Manual." 
Tune aborted-PG Circuit
PG cable wires are 
disconnected. 
Pulse generator is 
disconnected from the PG 
card. Check PG wiring.