Register: 0x0A

SCSI Selector ID (SSID)
Read Only

VAL

SCSI Valid

7

If VAL is asserted, then the two SCSI IDs are detected
on the bus during a bus-initiated selection or reselection,
and the following encoded destination SCSI ID bits are
valid. If VAL is deasserted, only one ID is present and the
contents of the encoded destination ID are meaningless.

R

Reserved

[6:4]

ENID

Encoded Destination SCSI ID

[3:0]

Reading the SSID register immediately after the
LSI53C1000R is selected or reselected returns the
binary-encoded SCSI ID of the device that performed the
operation. These bits are invalid for targets that are
selected under the single initiator option of the SCSI-1
specification. This condition is detected by examining the
VAL bit in this register.

Register: 0x0B

SCSI Bus Control Lines (SBCL)
Read Only

This register returns the SCSI control line status. A bit is set when the
corresponding SCSI control line is asserted. These bits are not latched;
they are a true representation of what is on the SCSI bus at the time the
register is read. The resulting read data is synchronized before being
presented to the PCI bus to prevent parity errors from being passed to
the system. This register is only used for diagnostics testing or operation
in the low level mode.