Figure2.4 regulated termination for ultra160 scsi, Regulated termination for ultra160 scsi – Avago Technologies LSI53C1000R User Manual

Page 70

Advertising
background image

2-40

Functional Description

Version 2.2

Copyright © 2000–2003 by LSI Logic Corporation. All rights reserved.

(or active) termination is recommended.

Figure 2.4

shows an active

terminator. TolerANT technology active negation can be used with either
termination network.

For information on terminators that support LVD, refer to the SPI-3 draft
standard.

Note:

If the LSI53C1000R is used in a design with an 8-bit SCSI
bus, all 16 data lines must be terminated.

Figure 2.4

Regulated Termination for Ultra160 SCSI

4
5
6
7
11
12
13
14
15
16

17

Line1

+

Line1

−

Line2

+

Line2

−

Line3

+

Line3

−

Line4

+

Line4

−

Line5

+

Line5

−

DISCONNECT

Line9

−

Line9

+

Line8

−

Line8

+

Line7

−

Line7

+

Line6

−

Line6

+

SE

LVD

HVD

DIFFSENS

DIFF B

32
31
30
29
25
24
23
22

33
34
35

20

21

4.7 mF

To LED
Drivers

SDP0

−

SDP0

+

SD7

−

SD7

+

SD6

−

SD6

+

SD5

−

SD5

+

SD0

+

SD0

−

SD1

+

SD1

−

SD2

+

SD2

−

SD3

+

SD3

−

SD4

+

SD4

−

51 K

1. DIFFSENS connects to the SCSI bus DIFFSENS line to detect what type of devices

(SE, LVD, or HVD) are connected to the SCSI bus.

2. DISCONNECT shuts down the terminator when it is not at the end of the bus. The

disconnect pin low enables the terminator.