Avago Technologies LSI53C1000R User Manual

Page 161

Advertising
background image

SCSI Registers

4-49

Version 2.2

Copyright © 2000–2003 by LSI Logic Corporation. All rights reserved.

•

A SCSI gross error occurs

•

An unexpected disconnect occurs

•

A SCSI reset occurs

•

A parity error is detected

•

The handshake-to-handshake timer expires

•

The general purpose timer expires

To determine which condition(s) caused the
interrupt, read the

SCSI Interrupt Status Zero (SIST0)

and

SCSI Interrupt Status One (SIST1)

registers.

DIP

DMA Interrupt Pending

0

This status bit is set when an interrupt condition is
detected in the DMA portion of the LSI53C1000R. The
following conditions cause a DMA interrupt to occur:

•

A PCI parity error is detected

•

A bus fault is detected

•

An abort condition is detected

•

A SCRIPTS instruction is executed in the single-step
mode

•

A SCRIPTS interrupt instruction is executed

•

An illegal instruction is detected

To determine exactly which condition(s) caused the
interrupt, read the

DMA Status (DSTAT)

register.