background image

MVI56E-MCM ♦ ControlLogix Platform

Diagnostics and Troubleshooting

Modbus Communication Module

User Manual

ProSoft Technology, Inc.

Page 81 of 199

June 18, 2014

2 On the shortcut menu, select C

HOOSE

M

ODULE

T

YPE

. This action opens the

Choose Module Type

dialog box.

3 In the Product Line Filter area of the dialog box, select MVI56E. In the Select

Module Type dropdown list, select MVI56E-MCM, and then click OK

to save

your settings and return to the ProSoft Configuration Builder window.

5.4.3 Assigning an IP Address in the Project

In this step, you assign an IP address for the MVI56E-MCM module using
ProSoft Configuration Builder. This becomes the permanent IP address for the
module after you download the configuration to the module (refer to Downloading
the Project to the Module (page 98)).
The module’s default IP address is 192.168.0.250.
1 Determine the network settings for your module, with the help of your network

administrator if necessary. You will need the following information:

o

IP address (fixed IP required) _____ . _____ . _____ . _____

o

Subnet mask

_____ . _____ . _____ . _____

o

Gateway address

_____ . _____ . _____ . _____

Note: The gateway address is optional, and is not required for networks that do not use a default
gateway.