Diagnosing the imc, Reading led conditions, Led conditions for the imc and imc/tpiu – Symmetricom EDGE CLOCK 1000 User Manual

Page 162

Advertising
background image

Chapter 6 Maintaining and Troubleshooting the TimeProvider
Diagnosing the IMC

162 TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

4. Retrieve the contents of the IOC memory stored in the IMC by issuing the

following command.

CPY-MEM:::::IMC,IOC,IOC;

This command may take more than two seconds to execute; if it does, then the
In-Process response is issued. See the TimeProvider TL1 Reference Guide for
more information on the CPY-MEM command.

If you have not stored the contents of the IOC memory in the IMC, then provision
the IOC using the procedures and commands described in

Chapter 4,

Provisioning the TimeProvider

.

5. Issue the following TL1 command to place the IOC in service:

ED-EQPT::IOC1:::IOCSTATE=INSRV;

6. Install the IOC into the right slot of the shelf and tighten the captive retaining

screws. This IOC will become the Standby IOC.

7. Wait for the IOC to reboot and qualify the reference inputs. During this time the

Active IOC updates the new IOC’s memory with current values.

8. Issue the following TL1 command to place the Standby IOC in service:

ED-EQPT::IOC2:::IOCSTATE=INSRV;

Diagnosing the IMC

Reading LED Conditions

Table 6-3

shows the function of the LED indicators on the front panel of the IMC and

IMC/TPIU.

Table 6-3. LED Conditions for the IMC and IMC/TPIU

LED Name

Condition

Description

Power

Green
Off

Power is On
Power is Off

Fail

Red
Off

Card failure
No failure

Alarm

Red
Off

Card alarm
No alarm

Critical

Red
Off

Critical system alarm
No alarm