Configuring WAN Access

Configuring inbound calls

MAX 6000/3000 Network Configuration Guide

3-65

Unspecified Max HDLC=0

Unspecified Max V110=0

Limiting all calls that do not specify a DNIS number

To specify that the MAX unit accepts twenty calls, of any type, that do not specify a DNIS
number, set the following parameters as shown:

Unspecified Max Calls=20

Unspecified Max Modem=20

Unspecified Max HDLC=20

Unspecified Max V110=20

Limiting V.110 calls to a specific DNIS number

To specify that the MAX unit accepts fifteen simultaneous V.110 calls that specify a DNIS
number of 1212 and allows 100 simultaneous calls to any DNIS number except 1212, set the
following parameters as shown:

DNIS #1 Max Calls=15

DNIS #1 Modem=0

DNIS #1 HDLC=0

DNIS #1 V110=15

Unspecified Max Calls=100

Unspecified Modem Calls=100

Unspecified HDLC Calls=0

Unspecified V110 Calls=0