Lucent Technologies 6000 User Manual

Page 240

Advertising
background image

4-108

MAX 6000/3000 Network Configuration Guide

Configuring Individual WAN Connections
Configuring POTS capability on the MAX 6000 and MAX 3000

Automatically prepend trunk digit

If you configure the MAX to use trunk groups and the callers do not enter a trunk digit when
dialing, you must configure a Call Routes profile to direct the unit to prepend a trunk digit.
With the following configuration, for example, the unit prepends a 9 to each outgoing call:

System

Sys Config

Use Trunk Grps=Yes

System

Call Routes

CRprofile1

Name=CRprofile 1

Active=Yes

Phone Number=

Src Slot=0

Src Port=0

Call Rte Type=Trunk-Voice

Dst Chan Grp=N/A or 0

Dst Trnk Grp=9

Dst Slot=0

Dst Port=0

Dial Plan=0

Rewrt Pattn=

Rewrt Replce=

Automatically strip trunk digit

If you configure the MAX not to use trunk groups and the callers manually enter a trunk digit
when dialing, you must configure a Call Routes profile to strip the trunk digit, as in the
following example:

System

Sys Config

Use Trunk Grps=No

System

Call Routes

CRprofile1

Name=CRprofile1

Active=Yes

Phone Number=

Src Slot=0

Src Port=0

Call Rte Type=Trunk-Voice

Dst Chan Grp=N/A or 0

Dst Trnk Grp=0

Dst Slot=0

Dst Port=0

Dial Plan=0

Rewrt Pattn=^.

Rewrt Replce=