Configuring Individual WAN Connections

Configuring POTS capability on the MAX 6000 and MAX 3000

MAX 6000/3000 Network Configuration Guide

4-105

You can configure the most specific slot and port by setting values other than zero. You can
configure the least specific slot and port by setting zero values. Table 4-1 shows the full-group
ordering from most specific to least specific.

As shown in Table 4-1, calls whose destination is a nonzero slot and a nonzero port are at the
top of the sort order, and calls to a zero slot and a zero port are at the bottom of the order. If a
match is within the same group in Table 4-1, the lower-numbered slot comes first, but if slots
are equal, the lower-numbered port comes first.

Table 4-2 shows the sorting order of a list of call routes, regardless of the order in which they
were initially entered. Field values that are not needed for this sorting (in this example) are not
shown.

Dst Port

From the most specific to the least specific.

Table 4-1. Full-group ordering of slot and port numbers

nonzero slot

nonzero port

nonzero slot

zero port

zero slot

zero port

Table 4-2. Example of sorting order

Phone
Number

Src Slot/
Src Port

Call Rte
Type

Dst Slot/
Dst Port

^5551212$

66

5551212

3/1

5551212

3/2

Trunk-Digital

5551212

3/2

Trunk-Voice

5551212

3/2

Trunk-Any

4/1

5551212

3/2

Trunk-Any

4/2

5551212

3/2

Trunk-Any

5/1

5551212

3/2

Trunk-Any

2/0

5551212

2/0

5551212

4/0

5551212

0/0

Parameter

Sort order within the parameter