X.25 clear cause codes, X.25 diagnostic field values, Table 6-5 – Lucent Technologies 6000 User Manual

Page 308: Clear cause codes -22, Table 6-6, X.25 diagnostic field values -22

Advertising
background image

6-22

MAX 6000/3000 Network Configuration Guide

Configuring X.25
Setting up X.25 PAD sessions

X.25 clear cause codes

Table 6-5 shows hexadecimal X.25 clear cause codes.

X.25 diagnostic field values

Table 6-6 shows the meanings of the X.25 diagnostic codes.

Table 6-5. Clear cause codes

Hex
value

Cause code

00

DTE Clear

01

Number busy

03

Invalid facility request

05

Network congestion

09

Out of order

0B

Access barred

0D

Not obtainable

11

Remote procedure error

13

Local procedure error

15

RPOA out of order

19

Reverse charging acceptance not subscribed

21

Incompatible destination

29

Fast select acceptance not subscribed

39

Ship absent

C1

Gateway-detected procedure error

C3

Gateway congestion

Table 6-6. X.25 diagnostic field values

Hex
value

Dec
value

Diagnostic

0

0

No additional information

1

1

Invalid P(S)

Advertising