Configuring IP Routing

Configuring WAN interfaces

MAX 6000/3000 Network Configuration Guide

9-37

configured to acquire its IP address dynamically. For example, the following a sample software
configuration presumes that the PC has a modem connection to the MAX unit:

Username=victor

Accept Assigned IP=Yes

IP address=Dynamic (or Assigned or N/A)

Netmask=255.255.255.255 (or None or N/A)

Default Gateway=None or N/A

Name Server=10.2.3.55

Domain suffix=abc.com

Baud rate=38400

Hardware handshaking ON

VAN Jacobsen compression ON

Configuring pools using local profiles

To configure the MAX unit to accept dial-in connections from Site B and assign an IP address:

1

Open Ethernet > Mod Config > WAN Options.

2

Set the Pool#1 Start parameter to specify the start address of the pool, and set the Pool#1
Count parameter to specify the number of contiguous addresses the pool includes. For
example:

Ethernet

Mod Config

WAN options…

Pool#1 start=10.12.253.1

Pool#1 count=126

Pool#1 name=Engineering Dept.

Pool only=Yes

Pool Summary=Yes

3

Open the Ether Options subprofile, then set the Proxy Mode parameter to Yes.

Ether options…

Proxy Mode=Yes

4

Exit the profile and, at the exit prompt, select the

exit and accept

option.

5

Open the Answer profile and set the Assign Adrs parameter to enable dynamic address
assignment and set the PPP Options > Route IP parameter to enable IP routing:

Ethernet

Answer

Assign Adrs=Yes

PPP options…

Route IP=Yes

6

Exit the profile and, at the exit prompt, select the

exit and accept

option.

7

Open a Connection profile for the dial-in user.

8

Set the Station parameter to specify the user’s name, set the Active parameter to activate
the profile, and specify the desired encapsulation options. For example:

Ethernet

Connections

Connection profile

Station=victor

Active=Yes

Encaps=PPP