Figure 9-14 example of a numbered interface -45 – Lucent Technologies 6000 User Manual

Page 409

Advertising
background image

Configuring IP Routing

Configuring WAN interfaces

MAX 6000/3000 Network Configuration Guide

9-45

Figure 9-14. Example of a numbered interface

The numbered interface addresses are:

IF Adrs=10.5.6.7/24

WAN Alias=10.5.6.8/24

Figure 9-14 also shows an unnumbered interface. The 10.1.2.3/32 connection uses a
single system-based address for both the MAX itself and the dial-in user. To configure the
unnumbered and numbered interfaces:

1

Open Ethernet > Mod Config > Ether Options and verify that the IP Adrs parameter is set
to the IP address of the Ethernet interface of the MAX unit:

Ethernet

Mod Config

Ether options...

IP Adrs=10.2.3.4/24

2

Exit the profile and, at the exit prompt, select the

exit and accept

option.

3

Open the Connection profile and configure the required parameters, then open the IP
Options subprofile.

4

Set the LAN Adrs parameter to specify the IP address of the Ethernet interface of the
remote device:

Ethernet

Connections

numbered

IP options...

LAN Adrs=10.7.8.9/24

5

Set the WAN Alias parameter to specify the numbered interface address for the remote
device:

IP options...

WAN Alias=10.5.6.8/24

6

Exit the profile and, at the exit prompt, select the

exit and accept

option.

Following is a comparable RADIUS profile:

numbered Password = "localpw"

Service-Type = Framed-User,

Framed-Protocol = PPP,

Ascend-Route-IP = Route-IP-Yes,

Framed-IP-Address = 10.5.6.8,

Framed-IP-Netmask = 255.255.255.0,

MAX

WAN

10.2.3.4/24

10.5.6.7/24

10.5.6.8/24

10.7.8.9/24

10.1.2.3/32