Configuring Individual WAN Connections

Configuring POTS capability on the MAX 6000 and MAX 3000

MAX 6000/3000 Network Configuration Guide

4-109

Route by area code

To route MAXPOTS calls on the basis of area codes, configure Call Routes profiles with Dial
Prefix Filter and New Trunk Group settings. Also make sure that the MAX unit is using trunk
groups and that the trunk groups are defined. For example, the following configuration routes
POTS calls to area code 201 through the first T1 line and all other POTS calls (including local
calls) through the second T1 line:

System

Sys Config

Use Trunk Grps=Yes

Net/T1, Net/E1

Line Config

LCprofile1

Name=LCprofile1

1st Line=Trunk

2nd Line=Trunk

Ch 1 TrnkGrp=7

Ch 2 TrnkGrp=7

...

...

Ch 24 TrnkGrp=7

2nd Line=Trunk

Ch 1 TrnkGrp=8

Ch 2 TrnkGrp=8

...

...

Ch 24 TrnkGrp=8

Call Routes

Call Routes

CRprofile1

Name=CRprofile1

Active=Yes

Phone Number=^1201.......

Src Slot=0

Src Port=0

Call Rte Type=Trunk-Voice

Dst Chan Grp=N/A or 0

Dst Trnk Grp=7

Dst Slot=0

Dst Port=0

Dial Plan=0

Rewrt Pattn=

Rewrt Replce=

Call Routes

Call Routes

CRprofile2

Name=CRprofile2

Active=Yes

Advertising