Exit the profile and, at the exit prompt, select the

exit and accept

option.

Establishing the connection

To bring up the Frame Relay manually, open the Connection profile and press Ctrl-D, then
select 1=Dial.

If you configure an Answer profile, an incoming call with the correct CLID or DNIS brings up
the session.

Configuring 64 switched Frame Relay connections

You can configure RADIUS to enable the MAX unit to support up to 64 switched Frame Relay
profiles. The unit authenticates and matches callers to switched Frame Relay profiles by
comparing DNIS or CLID information. The MAX unit dials outbound switched Frame Relay
connections on the basis of destination addresses of received packets. Previously, you could
configure Frame Relay profiles only from the VT100 interface.

Examples of RADIUS switched Frame Relay connections

Sample RADIUS Frame Relay Data Link profile

The following sample profile corresponds to both the example in “Sample RADIUS DNIS
profile” on page 5-36
and the example in “Sample RADIUS CLID profile” on page 5-37:

SWITCHED-FR-DTE Password="ascend", User-Service=

Dialout-

Framed-User

Ascend-FR-Profile-Name="SWITCHED-FR-DTE",

Ascend-Call-Type=Switched,

Ascend-FR-Type=Ascend-FR-DTE,

Ascend-FR-Link-Mgt=Ascend-FR-T1-617D,

Ascend-FR-N391=6,

Ascend-FR-DTE-N392=3,

Ascend-FR-DTE-N393=4,

Ascend-FR-T391=10

You must set Ascend-Call-Type to Switched. Also, the Frame Relay Data Link
profile’s name must match the value specified in the Ascend-FR-Profile-Name attribute
of the DNIS or CLID profile.

Sample RADIUS DNIS profile

Following is a sample RADIUS DNIS profile:

3762

Password=“Ascend-DNIS”

Ascend-Require-Auth=Not-Require-Auth

User-Service=Framed-User,

Framed-Protocol=FR,

Framed-Address=10.10.10.212,

Framed-Netmask=255.255.255.0,

Ascend-Route-IP=Route-IP-Yes,

Advertising
This manual is related to the following products: