Lucent Technologies 6000 User Manual

Page 440

Advertising
background image

11-6

MAX 6000/3000 Network Configuration Guide

Setting Up Virtual Private Networks
Configuring ATMP tunnels

Station=name-of-home-agent

Active=Yes

Dial #=555-1212

Route IP=Yes

IP options...

LAN Adrs=10.1.2.3/24

Following are the parameters (shown with sample settings) for using RADIUS authentication:

Ethernet

Mod Config

Auth...

Auth=RADIUS

Auth Host #1=10.23.45.11/24

Auth Host #2=0.0.0.0/0

Auth Host #3=0.0.0.0/0

Auth Port=1645

Auth Timeout=1

Auth Key-=[]

Auth Pool=No

Auth Req=Yes

Password Server=No

Password Port=N/A

Local Profile First=No

Sess Timer=0

Auth Src Port=0

Auth Send Attr 6,7=Yes

Following are the parameters (shown with sample settings) for creating RADIUS user profiles
for mobile clients running TCP/IP:

node1 Password="top-secret"

Ascend-Metric=2,

Framed-Protocol=PPP,

Service-Type= * check these in this section

Ascend-IP-Route=Route-IP-Yes,

Framed-IP-Address=200.1.1.2,

Framed-IP-Netmask=255.255.255.0,

Ascend-Primary-Home-Agent=10.1.2.3,

Ascend-Home-Agent-Password="private"

Ascend-Home-Agent-UDP-Port=5150

Tunnel-Type=ATMP,

Tunnel-Server-Endpoint="atmp-ha1.example.com",

Tunnel-Password="tunnel-password"

Following are the parameters (shown with sample settings) for creating RADIUS user profiles
for mobile clients running NetWare:

node2 Password="ipx-unit"

User-Service=Framed-User,

Ascend-Route-IPX=Route-IPX-Yes,

Framed-Protocol=PPP,

Ascend-IPX-Peer-Mode=IPX-Peer-Dialin,

Framed-IPX-Network=40000000,

Ascend-IPX-Node-Addr=123456789012,

Advertising