The mp+ parameters, Channel counts and bandwidth allocation parameters, Auxiliary password for added channels – Lucent Technologies 6000 User Manual

Page 185: Bandwidth monitoring, Settings in a radius profile, The mp+ parameters -53, Settings in a radius profile -53

Advertising
background image

Configuring Individual WAN Connections

Configuring MP, MP+ and BACP connections

MAX 6000/3000 Network Configuration Guide

4-53

Target Util=70

Idle Pct=0

The MP+ parameters

This section provides some background information about MP+ connections. For detailed
information about each parameter, see the MAX Reference.

Channel counts and bandwidth allocation parameters

BACP and MP+ use the same criteria for increasing or decreasing bandwidth for a connection.
For details about the bandwidth allocation parameters, see“The MP and BACP parameters” on
page 4-47 and
“Guidelines for configuring bandwidth criteria” on page 4-49.

Auxiliary password for added channels

The Aux Send PW parameter can specify another password for authenticating subsequent links
as they are dialed. For details, see the MAX Security Supplement.

Bandwidth monitoring

In a Connection profile’s Encaps Options subprofile, the DBA Monitor parameter specifies
whether bandwidth criteria for adding or dropping links are applied to traffic received across
the link, transmitted across the link, or both. If you set DBA Monitor to None on both sides of
the link, you disable bandwidth on demand.

Settings in a RADIUS profile

A RADIUS user profile can specify the following attributes:

Attribute

Value

Framed-Protocol (7)

Encapsulation protocol. MPP (256) indicates an MP+ connection
with another Ascend unit.

Ascend-History-Weigh-T
ype (239)

Algorithm for calculating average line utilization (ALU) over a
certain number of seconds.

Ascend-DBA-Monitor
(171)

Criteria for adding or subtracting bandwidth from the connection.
You can specify DBA-Transmit (0), DBA-Transmit-Recv (1), or
DBA-None (3). If both sides of the link have
Bandwidth-Monitor-Direction set to None, DBA is disabled.

Ascend-Inc-Channel-Cou
nt (236)

Number of channels the MAX can add at one time, subject to the
setting of the Parallel-Dialing parameter in the System profile.

Ascend-Dec-Channel-Co
unt (237)

Number of channels the MAX can subtract at one time, dropping
the newest channels first.

Ascend-Seconds-Of-Hist
ory (238)

Number of seconds to use as the basis for calculating average line
utilization (ALU).

Ascend-Add-Seconds
(240)

Number of seconds for which ALU must persist beyond the
Target-Utilization threshold before the MAX adds bandwidth.