Configuring host/bri lines, Configuring host/bri lines -40 – Lucent Technologies 6000 User Manual

Page 84

Advertising
background image

3-40

MAX 6000/3000 Network Configuration Guide

Configuring WAN Access
Configuring Host/BRI lines

InOctets and OutOctets show the number of bytes received by the answering device and
transmitted by the calling device, respectively.

Note:

When an ISDN call disconnects in Germany, the ISDN switch sends call billing

information to the call originator as part of the call tear-down process. For lines that use the
German 1TR6 switch type, you can access ISDN call charges in the Ascend Enterprise MIB
through SNMP management utilities.

Configuring Host/BRI lines

The Host/BRI module provides up to eight local ISDN BRI lines. A line terminating one of
these local ISDN BRI lines might be a MAX unit (or any BRI device) on its own local Ethernet
segment, or a Desktop video device with its own BRI line and built-in terminal adapter. When
a MAX unit is connected to a Host/BRI line, it appears to be an AT&T switch.

Terminal Equipment devices on Host/BRI lines can call each other, making local
net-to-Net/BRI calls. These local calls never go out to the WAN. They make use of the BRI
bandwidth internally. They can also send and receive calls from the WAN. To the actual WAN
switch, the MAX unit appears as the call’s end point. Routing to the Host/BRI line is handled
internally.

Note:

TAOS supports the European ISDN protocol for the eight-port Host/BRI card on MAX

units that are configured as Network Terminating (NT) devices (see ISDN TE/NT Mode
parameter in the MAX Reference). You can select this carrier switch type by setting the Switch
Type parameter to NET3.

To begin configuring Host/BRI lines, open a Host/BRI > Line Config profile and set the
following parameters:

Then set the following parameters in each Line N subprofile:

Parameter

Specifies

Name

Descriptive name for the profile. You can configure several profiles in a
Host/BRI sot and activate a profile when it is needed. (This parameter is
optional. Functionality is not affected if you do not enter a value.)

Switch Type

Type of switch (carrier-specific) that provides the ISDN service for the
MAX.

BRI Analog
Encode

Support for user-selectable analog encoding for the BRI interface. If you
are going to receive modem calls, you can set this parameter to specify
the encoding type.

Parameter

Specifies

Enabled

Availability of the ISDN BRI line. If you set the Enabled parameter to
No, the line is not available for use.

Dial Plan

Whether the module uses trunk groups or the extended dial plan to send
and receive calls. (For details about dial plans, see “Configuring
outbound calls” on page 3-69.
)

Advertising
This manual is related to the following products: