Lucent Technologies 6000 User Manual

Page 256

Advertising
background image

5-8

Preliminary January 4, 2001

MAX 6000/3000 Network Configuration Guide

Configuring Frame Relay
Defining Frame Relay link operations

The following attributes can be used to define a frdlink pseudo-user profile:

Attribute

Value

Ascend-FR-Profile-
Name (180)

A Frame-Relay profile name (up to 15 characters), to be
referenced in user profiles that make use of this datalink.

Ascend-FR-Nailed-Grp
(158)

Group number assigned to nailed bandwidth in a line profile, such
as a T1 or E1 profile. The default is 1. Make sure the Frame-Relay
profile specifies the correct group number. If the channels are on
nailed T1, make sure that the number of channels the MAX uses
for the link matches the number of channels used by the device at
the other end of the link, and that only one T1 profile specifies the
Nailed-Group number to be used by the Frame Relay datalink.

Ascend-Call-Type (177)

Type of nailed connection: Nailed (1), Nailed/Mpp (2), or Perm/
Switched (3). Nailed is the default.

Ascend-Data-Svc (247)

Type of data service on the nailed link.Typically set to Nailed-64K
for a Frame Relay datalink.

Ascend-FR-Link-Mgt
(160)

The link management protocol. Settings are Ascend-FR-No-Link-
Mgt (0) (link management protocol is disabled), Ascend-FR-T1-
617D (1) (Annex D), and Ascend-FR-Q-933A (2)(CCITT Q.933
Annex A). Ascend-FR-No-Link-Mgt is the default.

To ensure interoperability with equipment from different vendors,
the same version of management protocol must be used at each
end of the Frame Relay link.

Ascend-FR-Type (159)

Type of operations performed by the MAX on this interface.
Settings are Ascend-FR-DTE (0), Ascend-FR-DCE (1), or
Ascend-FR-NNI (2). Ascend-FR-DTE is the default. (For more
information, see “Examples of a UNI-DTE link interface” on page
5-9
, “Examples of a UNI-DCE link interface” on page 5-10, and
“Examples of an NNI link interface” on page 5-12.)

Ascend-FR-N391 (161)

Number of T391 polling cycles between full Status Enquiry
messages. The default is 6, which indicates that after 6 status
requests spaced Ascend-FR-T391 seconds apart, the UNI-DTE
device requests a Full status report. Does not apply when Ascend-
FR-Type is Ascend-FR-DCE.

Ascend-FR-DTE-N392
(163)

Number of errors which, if occurring in the number of DTE
monitored events specified by Ascend-FR-DTE-N393, causes the
user-side to declare the network-side procedures inactive. The
value should be less than that of Ascend-FR-DTE-N393l (which
can be from 1 to 10). The default value is 3. Does not apply when
Ascend-FR-Type is Ascend-FR-DCE.

Ascend-FR-DTE-N393
(165)

DTE monitored event count (from 1 to 10). The default is 4. Does
not apply when Ascend-FR-Type is Ascend-FR-DCE.