Lucent Technologies 6000 User Manual

Page 243

Advertising
background image

Configuring Individual WAN Connections

Configuring POTS capability on the MAX 6000 and MAX 3000

MAX 6000/3000 Network Configuration Guide

4-111

Port-to-port routing

This routing allows the routing of calls from one POTS port on a MAX to another POTS port
on the same MAX. The ports do not need to be on the same MAXPOTS slot card, and no other
trunks are necessary. You can configure calls 4001 and 4002 to be routed to POTS ports 1 and
2, respectively, on MAXPOTS slot 3 card. For example:

System

Sys Config

System

Call Routes

CRprofile1

Name=CRprofile1

Active=Yes

Phone Number=4001

Src Slot=0

Src Port=0

Call Rte Type=Trunk-Any

Dst Chan Grp=0

Dst Trnk Grp=0

Dst Slot=3

Dst Port=1

System

Call Routes

CRprofile2

Name=CRprofile2

Active=Yes

Phone Number=4002

Src Slot=0

Src Port=0

Call Rte Type=Trunk-Any

Dst Chan Grp=0

Dst Trnk Grp=0

Dst Slot=3

Dst Port=2

You can define the call route to allow calls from POTS port 8, dialing telephone number 4001
to connect to POTS port 4. For example:

System

Call Routes

CRprofile3

Name=CRprofile3

Active=Yes

Phone Number=4001

Src Slot=3

Src Port=8

Call Rte Type=Trunk-Any

Dst Chan Grp=0

Dst Trnk Grp=0

Advertising