Configuring the max at site a – Lucent Technologies 6000 User Manual

Page 500

Advertising
background image

12-14

MAX 6000/3000 Network Configuration Guide

Configuring IPX Routing
Configuring IPX routing connections

Figure 12-2. A connection with NetWare servers on both sides

Site A and Site B each have Novell LANs that support NetWare 3.12 and NetWare 4 servers,
NetWare clients, and a MAX unit. The NetWare server at Site A has the following
configuration settings

:

Name=SERVER-1

internal net CFC12345

Load 3c509 name=ipx-card frame=ETHERNET_8023

Bind ipx ipx-card net=1234ABCD

The NetWare server at Site B has the following configuration settings:

Name=SERVER-2

internal net 013DE888

Load 3c509 name=net-card frame=ETHERNET_8023

Bind ipx net-card net=9999ABFF

To establish the connection shown in Figure 12-2, you would configure the unit at Site A,
enable IPX routing for its Ethernet interface, and configure a static route to the remote server.
The same procedures would apply to Site B.

Configuring the MAX at Site A

On the MAX Site A:

1

Make sure you assign the MAX unit a system name in the System > System Config
profile. This example uses the name SITEAGW.

2

If you have not done so already, configure the Ethernet > Mod Config profile (as described
in “Enabling IPX routing in the MAX” on page 12-5).

3

In Answer > PPP Options, enable IPX routing and PAP/CHAP authentication, and then
close the Answer profile.

Ethernet

Answer

PPP options...

Route IPX=Yes

Recv Auth=Either

Site B

Site A

Net=9999ABFF

Net=1234ABCD

Net=AABBCC11

Net=11223344

Internal net=CFC12345

Internal Net=013DE888

WAN

SITEAGW

MAX

SITEBGW

MAX