Configuring WAN Access

Configuring MAXDAX

MAX 6000/3000 Network Configuration Guide

3-85

Routing calls on the basis of the channel on which MAX 2 receives the call

This example illustrates a different call-routing process for the MAX unit labeled MAX 2 in
Figure 3-5. The physical environment for this example is the same as displayed in Figure 3-5,
but MAX 2 routes calls on the basis of the channel on which it receives the call from MAX 1.

Note:

Because MAX 2 considers Answer Plan profiles after determining whether it should

route on the basis of specific channels, the system administrator could leave the configuration
from the preceding example as it is.

The system administrator configures MAX 1 to deliver calls to MAX 2 on specific channels.
MAX 1 sends calls with calling number 1234 to channel 1 or 2 of the leased T1 line on
MAX 2. The system administrator configures the Net/T1 > Line Config > Line Config profile
> Line 1 > Net2Net Incoming Calls profile as follows:

Net/T1

Line Config

Line Config profile

Line 1...

Net2Net Incoming Calls

Ch 1=Switched

Ch 1 Dest ChanGroup=1

Ch 1 Dial Plan #=0

Ch 1 #DialPlanSelDigits=2

Ch 2=Switched

Ch 2 Dest ChanGroup=1

Ch 2 Dial Plan #=0

Ch 2 #DialPlanSelDigits=2

Ch 3=Switched

Ch 3 Dest ChanGroup=0

Ch 3 Dial Plan #=0

Ch 3 #DialPlanSelDigits=0

MAX 2 routes any call it receives on channel 1 or 2 to the first available channel assigned to
channel group 1. MAX 2 identifies the Dial Plan profile number by examining the leading two
digits of the called number.

Because the system administrator sets Dest ChanGroup to 1 in the Net2Net Incoming Call
profile, at least one channel of the PRI line must belong to channel group 1. The system
administrator configures the outgoing-calls profile as follows:

Net/T1

Line Config

Line Config profile

Line 1...

Net2Net ChanGroup ID

Ch 1=Switched

Ch 1 ChanGroup=1

Ch 2=Switched

Ch 2 ChanGroup=1

The system administrator can assign more channels to channel group 1 if users connected to