3-24

MAX 6000/3000 Network Configuration Guide

Configuring WAN Access
Configuring E1 lines

Using MAXDAX

MAXDAX enables you to route incoming calls from PRI lines to specific outgoing channels
on the same or different PRI lines. To implement MAXDAX, you must set parameters in the
Net2Net Incoming Calls and Net2Net ChanGroup ID profiles. In the Net2Net Incoming Calls
profile, you define parameters used in configuring channels on which the MAX unit receives
incoming calls. In the Net2Net ChanGroup ID profile, you define parameters used in
configuring channels for outbound calls.

For complete information about MAXDAX, see “Configuring MAXDAX” on page 3-74. Or,
for detailed information about each parameter, see the MAX Reference.

Following are the parameters you set in the Net/E1 > Line Config profile > Line N > Net2Net
Incoming Calls profile:

In the Net/E1 > Line Config > Line Config profile > Line N > Net2Net ChanGroup ID profile,
you set the following parameters:

Configuring channels

Each built-in E1 connection supports 32 channels, each of which can support one
single-channel connection. Depending on the signaling mode used on the line, all 32 channels
are available for user data, or 31 channels are available for data and the 32nd channel is
reserved for signaling. Each channel can be either switched or nailed. You can assign a
switched channel to a slot/port combination. To make a nailed channel available to a
Connection or call profile, you assign the channel to a group. You can also assign channels to
hunt groups. (For the definition of call profile, see “Assigning nailed channels to groups” on
page 3-12.
)

Each E1 line supports 32 channels, of which one is used for framing. Also, you can use one of
the channels for a PRI signalling. The Ch N parameters are repeated for each channel in the
line

Parameter

Specifies

Ch N

A switched connection for MAXDAX. That is, you must set Ch N
to Switched.

Ch N Dest ChanGroup

The channel group number to which the MAX unit directs
outbound calls.

Ch N Dial Plan #

A Dial Plan profile for the calls received by this channel.

Ch N #DialPlanSelDigits The number of leading digits the unit strips from the called

number.

Parameter

Specifies

Ch N

A switched connection for MAXDAX. That is, you must set Ch N
to Switched.

Ch N ChanGroup

The group to which the channel is assigned.