Connecting to the central office switch, Signaling mode, Connecting to the central office switch -8 – Lucent Technologies 6000 User Manual

Page 52: Signaling mode -8

Advertising
background image

3-8

MAX 6000/3000 Network Configuration Guide

Configuring WAN Access
Configuring T1 lines

Connecting to the Central Office switch

To configure a line’s connection to the Central Office switch, open the Net/T1 > Line Config >
Line Config profile > Line N subprofile for the line and set the following parameters:

For detailed information about each parameter, see the MAX Reference.

Signaling mode

You must configure the signaling type (Sig Mode) for each T1 line.

If you set Sig Mode to ISDN_NFAS, you can also establish an interface ID or NFAS ID
number for this type of signaling. You must specify a different interface ID for each NFAS
line.

Parameter

Specifies

Sig Mode

The signaling type for the line.

NFAS ID Num

An interface ID number for a line using Non-Facility Associated
Signaling (NFAS). Each NFAS line must have a different ID number.

Rob Ctl

The robbed-bit call-control mechanism that the MAX unit uses for
inband signaling.

Switch Type

Type of switch (carrier specific) providing the ISDN service.

Framing Mode

Physical-layer frame format of the T1 line.

Front End

Type of interface used on the T1/PRI port. Select CSU (the default) if
you plan to use the MAX unit’s internal CSU, or select DSX if you
plan to connect the port to other equipment that provides the interface
to the WAN, (an external CSU, for example), and disable the internal
CSU.

Encoding

Type of encoding that the line uses at the physical-link layer.

Length

The distance between the CSU and the MAX unit. Applies to a MAX
using external CSUs only.

Buildout

Amount of attenuation, in decibels, to apply to the internal CSU.
Consider specifying a value if the MAX is using an internal CSU too
near a repeater. For additional information, consult your carrier.

Clock Source

That the line can (Yes) or cannot (No) be used as the clock source for
timing synchronous transmissions between the sending and the
receiving device. A MAX unit only has one clock source. The first line
that comes up is the clock source for all the lines. If you set this
parameter to No, the MAX uses its internal clock.

Collect DNIS/ANI

That DNIS and CLID information from the switch are (Yes) or are not
(No) available for authentication and accounting. Applies to inband
signaling only. With the Yes setting, the Digital Signal Processor
(DSP) decodes the calling and called DTMF digits.

Send Disc

Number of seconds the MAX unit waits, from the time the call is
presented, before clearing the call.