The combinet bridging parameters, Enabling bridging, Requiring a password from the remote bridge – Lucent Technologies 6000 User Manual

Page 224: Configuring line-integrity monitoring, Base channel count, Compression, The combinet bridging parameters -92, Base channel count -92 compression -92

Advertising
background image

4-92

MAX 6000/3000 Network Configuration Guide

Configuring Individual WAN Connections
Configuring a Combinet connection

The Combinet bridging parameters

This section provides some background information about a Combinet configuration.

Specifying the hardware address of the remote Combinet bridge

The (Connection profile) Station parameter must specify the MAC address of the remote
Combinet bridging device.

Enabling bridging

A Combinet connection is always a bridging connection, so the Bridge parameter in the
Connection profile must be set to Yes. If the Bridge parameter is N/A, bridging has not been
enabled in the Ethernet profile (as described in Chapter 14, “Configuring Packet Bridging”).

Requiring a password from the remote bridge

The Password Reqd parameter specifies that a password will be required to authenticate
Combinet connections.You can specify that an individual Combinet connection does not
require a password exchange, even if the Answer profile specifies that Combinet passwords
are required.

Specifying passwords to exchange with the remote bridge

The Send PW parameter specifies the password sent to the remote device. It must match the
password expected from the MAX unit. The Recv PW parameter specifies the password sent to
the unit from the remote device.

Configuring line-integrity monitoring

The (Answer profile) Interval parameter specifies the number of seconds between
transmissions of Combinet line-integrity packets. You can specify a number between 5 and 50.
If the MAX unit does not receive a Combinet line-integrity packet within the specified
interval, it disconnects the call.

Base channel count

The (Connection profile) Base Ch Count parameter specifies the base number of channels to
use when setting up the call. It can be set to 1 (for 64 Kbps) or 2 (for 128 Kbps).

Compression

The (Connection profile) Compression parameter enables or disables STACKER LZS
compression/decompression. Both sides of the link must enable compression or it is not used.

Advertising