4-14

MAX 6000/3000 Network Configuration Guide

Configuring Individual WAN Connections
The Answer profile

Filter-related parameters

The Answer > Session Options subprofile contains the following filter-related parameters:

Timing parameters

The Answer > Session Options timing parameters define how long a session can remain
inactive before a call is cleared, whether the MAX unit uses the terminal-server idle timer, and
how long a terminal server can remain idle before the session disconnects. Following are the
parameters:

Miscellaneous Session Options parameters

The following Answer > Session Options parameters further define the session for an
incoming call:

Parameter

Specifies

Data Filter

Number of a filter used to determine if packets should be forwarded or
dropped. If both a call filter and data filter are applied to a connection,
the MAX unit applies a call filter after applying a data filter. (Only
those packets that the data filter forwards can reach the call filter.)

Call Filter

Number of a filter used to determine if a packet should cause the idle
timer to be reset or a call to be placed. If both a call filter and data filter
are applied to a connection, the unit applies a call filter after applying a
data filter. (Only those packets that the data filter forwards can reach
the call filter.)

Filter Persistence

Whether or not the filter or firewall assigned to an Answer profile
should persist after the call has been disconnected.

Parameter

Specifies

Idle

Number of seconds the MAX unit waits before clearing a call when a
session is inactive.

TS Idle Mode

Whether or not the unit uses the terminal-server idle timer and, if so,
whether both the user and host must be idle before the unit disconnects
the session.

TS Idle

Number of seconds that a terminal-server connection must be idle
before the unit disconnects the session.

Parameter

Specifies

Max Call Duration

Maximum duration in minutes of an established session for an
incoming call. The connection is checked once per minute, so the
actual time of the call is slightly longer (usually less than a minute
longer) than the actual time you set.

Preempt

Number of idle seconds the MAX unit waits before using one of the
channels of an idle link for a new call.