Configuring Packet Bridging

Configuring bridged connections

MAX 6000/3000 Network Configuration Guide

14-11

Encaps options...

Send Auth=CHAP

Recv PW=localpw

Send PW=remotepw

5

Exit the profile and, at the exit prompt, select the exit and accept option.

6

Open an Ethernet > Bridge Adrs profile.

7

Specify a node’s Ethernet address and the IP address (if known) on the remote network:

Ethernet

Bridge Adrs

Bridge Adrs profile

Enet Adrs=0080AD12CF9B

Net Adrs=0.0.0.0

8

Specify the number of the Connection profile to bring up a link to the remote network:

Ethernet

Bridge Adrs

Bridge Adrs profile

Connection#=5

9

Exit the profile and, at the exit prompt, select the exit and accept option.

To configure the Site B MAX unit for the bridged connection:

1

Make sure the remote MAX unit has been assigned a station name in its System > Sys
Config profile. This example uses the name SITEBGW for the remote unit.

2

Turn on bridging and specify an authentication protocol in the Site B MAX unit’s Answer
profile. For example:

Ethernet

Answer

PPP options...

Bridge=Yes

Recv Auth=Either

3

Open Connection profile #2 on the Site B MAX and set the following parameters:

Ethernet

Connections

profile #2...

Station=SITEAGW

Active=Yes

Encaps=PPP

Bridge=Yes

Dial Brdcast=No

Note:

Dial Brdcast is not needed because of the Bridge Adrs profile, configured next.

4

Configure password authentication. For example:

Encaps options...

Send Auth=CHAP

Recv PW=remotepw

Send PW=localpw

5

Exit the profile and, at the exit prompt, select the exit and accept option.

6

Open an Ethernet > Bridge Adrs profile.

7

Specify a node’s Ethernet address and the IP address (if known) on the remote network: