Set the PRI # Type parameter to the type of telephone number the unit dials for the
outgoing call:

National specifies telephone numbers within the United States.

Intl specifies telephone numbers outside the United States.

Local specifies telephone numbers within your Centrex group.

Inherit specifies the same PRI # Type value assigned to the incoming call.

PRI # Type does not apply to outbound calls on inband T1 lines.

5

Set the Transit # parameter to a dialing prefix the unit uses when making the outbound
call.

The default (null) directs the unit to use any available IEC for the long distance call. You
can also specify 288 (AT&T), 222 (MCI), or 333 (Sprint).

Transit # does not apply to outbound calls on inband T1 lines.

6

Set the Bill # parameter if you use a different telephone number for billing purposes.

In most cases, you can leave this setting blank. If you have questions, ask your service
provider.

7

Set the PrependDigits parameter to specify the digits that the unit prepends to the called
number before making the outgoing call.

8

Set the Dest # parameter to the telephone number to be dialed for the outgoing call.

9

Exit the profile and, at the exit prompt, select the exit and accept option.

When the unit receives a call on the channel you specified in the Net2Net Incoming Calls
profile, the unit makes the outgoing call on the first available channel in the channel group you
specify for the Ch N Dest ChanGroup parameter. To make the call, the unit uses the Dial Plan
profile you specify for the

Ch N Dial Plan # parameter.

Configuring the MAX unit to use a caller-defined Dial Plan profile

You can allow callers to specify the Dial Plan profile the MAX unit uses for the outgoing call.
With this type of configuration, callers prepend the Dial Plan profile number to the telephone
number they dial. The unit strips either one or two digits from the called number, and uses
them to determine the Dial Plan profile.

To configure the unit to use a caller-defined Dial Plan profile, you must first configure a
destination channel-group and then specify the Dial Plan profile.

To configure a destination channel-group:

1

Open Net/T1 (E1) > Line Config > Line Config profile > Line N > Net2Net Incoming
Calls.

2

For each incoming channel for which you want to specify a caller-defined Dial Plan
profile:

Set the Ch N parameter to Switched.

Set the Ch N Dest ChanGroup parameter to a value that matches the number of a
group you created by setting Ch N ChanGroup parameters as described in
“Configuring channels on which the MAX unit sends outgoing calls” on page 3-76.

Set the Ch N Dial Plan # parameter to 0 (zero). The zero disables static channel
assignment of a Dial Plan profile on the unit.