FXS line profiles

There are five possible slot profiles for each MAXPOTS slot card. The first profile (default) is
always the active profile. You can save alternative configurations in the other four profiles.

Configuring an FXS line profile

To configure a slot (or line) profile in Main > Analog FXS > FXS Config > FXS Configuration
profile
> Line profile, use the following parameters:

Saving alternative configurations

To copy the active profile to one of the alternate live profiles, proceed as follows:

1

From Analog FXS > FXS Config, select the active profile.

The active profile appears.

2

Press Ctrl-D to access the DO menu.

The DO menu appears.

3

Select S (Save).

4

Select the alternate live profile by using the Up Arrow and, Down Arrow keys, and press
Enter.

The active profile is saved to the specified alternative profile.

Activating an alternative profile

To activate one of the alternative profiles, copy any alternative profile to the active profile,
proceed as follows:

1

From Analog FXS > FXS Config, select the alternative (101, 102, 103, or 104) profile you
want to activate.

Parameter

Specifies

Name

Name of the profile.

Dial-Enabled

Enable/disable outbound dialing through this profile’s POTS port.

Inc CallerID Info

Include/do not include CallerID information for calls from this port.

Clid Number

Telephone number of the caller.

Answer-Enabled

Enable/disable answering of calls on this profile’s POTS port.

CallerID

Do/do not forward caller-ID information to the POTS port. MAXPOTS
only supports the Bellcore Type I callerID format which might not be
supported in all countries.

Forward Disc

Far-end disconnect indication is/is not forwarded to the POTS port.

Rx Gain

Gain applied to the signal received from the connected equipment.

Tx Gain

Gain of the signal transmitted to the equipment.

Signalling

The signaling used on an analog loop. Regular telephones use Loopstart.

GndStart Ring

Apply/do not apply ringing voltage to the ground start line.