background image

5-32

Preliminary January 4, 2001

MAX 6000/3000 Network Configuration Guide

Configuring Frame Relay
Configuring the MAX as a Frame Relay switch

The next set of parameters on MAX-39 specifies the circuit between its two Frame Relay
interfaces:

Ethernet

Connections

max42

Name=max42

Active=Yes

Encaps=FR-Cir

Route IP=No

Encaps options

FR Prof=nni-42

DLCI=200

FR Circuit=cir-39

Ethernet

Connections

max39

Name=max39

Active=Yes

Encaps=FR-Cir

Route IP=No

Encaps options

FR Prof=dce-p130

DLCI=300

FR Circuit=cir-39

Using RADIUS profiles

The following profiles define the datalinks from MAX-42 to the MAX and MAX-39:

frdlink-max-25 Password="ascend", User-Service=Dialout-Framed-User

Ascend-FR-Profile-Name="dce-max",

Ascend-Call-Type=Nailed,

Ascend-FR-Type=Ascend-FR-DCE,

Ascend-FR-Nailed-Grp=555

frdlink-max-26 Password="ascend", User-Service=Dialout-Framed-User

Ascend-FR-Profile-Name="nni-39",

Ascend-Call-Type=Nailed,

Ascend-FR-Type=Ascend-FR-NNI,

Ascend-FR-Nailed-Grp=999

The next set of profiles specifies the circuit on MAX-42:

permconn-max-14 Password="ascend", User-Service=Dialout-Framed-User

User-Name="max"

Framed-Protocol=FR-CIR,

Ascend-Route-IP=Route-IP-No,

Ascend-FR-DLCI=100,

Ascend-FR-Profile-Name="dce-max",

Ascend-FR-Circuit-Name="cir-42"