Example of x.25 pad, Setting up x.25 pad sessions, X.3 parameters and profiles – Lucent Technologies 6000 User Manual

Page 300: Example of x.25 pad -14, Setting up x.25 pad sessions -14, X.3 parameters and profiles -14, Table 6-2, X.3 parameters -14

Advertising
background image

6-14

MAX 6000/3000 Network Configuration Guide

Configuring X.25
Setting up X.25 PAD sessions

4

Open the Encaps Options subprofile and specify the name of the X.25 profile that carries
this connection.

5

Specify the password that authenticates the user connection.

6

Specify a default X.3 parameter profile for this connection.

7

Specify the X.121 address and password for automatic calling.

8

Exit the profile and, at the exit prompt, select the exit and accept option.

Example of X.25 PAD

Ethernet

Answer

Encaps...

X25/PAD=Yes

Ethernet

Connections

rchan

Name=rchan

Active=Yes

Encaps=X25/PAD

Encaps options...

X.25 Prof=ATT

Recv PW=localpw

X.3 Param Prof=CRT

Auto-Call X.121 Addr=031344159782111 *Dpassword

Setting up X.25 PAD sessions

This section describes some of the PAD commands and X.3 parameter profiles that can affect
how users’ terminal sessions operate.

X.3 parameters and profiles

By setting one or more X.3 parameters or by applying an X.3 profile, the user’s terminal or
host DTE can modify PAD operations. This section lists the X.3 parameters and profiles and
then describes how to set them from the PAD. Table 6-2 lists the X.3 parameters, numbered
1–22.

Table 6-2. X.3 parameters

Parameter

Description

Possible values

1

PAD recall

0—Escape not allowed
1—Escape allowed (the default)

2

Echo

0—No echo
1—Echo (the default)

Advertising
This manual is related to the following products: